Tag: veterinary imaging
Showing all 3 results
-
Flat Panel Detector IRAY Venu 1717VX
€ 9.900,00Add to cartVenu 1717XV is a 17 × 17 inch tethered flat panel detector for digital X-ray imaging, designed for veterinary DR systems. It features amorphous silicon detector technology with a CsI scintillator, a 2912 × 2912 pixel matrix, and 16-bit A/D conversion, delivering high-quality images at a low radiation dose. With a 139 µm pixel pitch, 3.6 lp/mm spatial resolution, Ethernet interface, and fast image acquisition (3 s preview / 5 s full image), the Venu 1717XV ensures an efficient and reliable imaging workflow for both new and retrofit X-ray systems.
-
Flat Panel Detector VA FP33
€ 9.800,00Add to cartThe 17×17 inch digital X-ray flat panel detector delivers high-resolution, low-dose imaging for medical, veterinary, and industrial applications. Featuring A-Si technology, CsI scintillator, and multi-gain functionality, it offers fast image acquisition, wide dynamic range, and reliable performance for modern digital radiography (DR) systems. Lightweight, durable, and compatible with Windows-based software, it ensures precise diagnostics every time.
-
VET DX-V1 – Digital Veterinary X-Ray System
€ 19.800,00Add to cartVET DX-V1 – Digital Veterinary X-Ray System
The VET DX-V1 is a modern digital veterinary X-ray system, ideal for animal clinics and veterinary practices. It combines high-resolution imaging, intuitive software, flexible patient positioning, and fast diagnostics. With a powerful X-ray generator, Toshiba X-ray tube, Careview flat-panel detector, and touchscreen control computer, it enables precise diagnoses, efficient workflows, and safe patient care.
Category Parameter Specification Generator Power Supply Voltage Single-phase 3-wire 220V ±22V Supply Frequency 50Hz ±1Hz Rated Power 32 kW Max Output Current 400 mA Operating Frequency ≥300 Hz Current Regulation Range 10 mA ~ 400 mA Tube Voltage Range 40 kV ~ 150 kV Exposure Time 0.001 s ~ 10.0 s Current-Time Product 0.1 mAs ~ 320 mAs X-Ray Tube Maximum Peak Voltage 125 kV Spot Focus Small: 1.0 mm / Large: 2.0 mm Anode Power 21 kW / 42.5 kW Anode Speed 2700 rpm Target Angle 16° Anode Heat Capacity 140 KHU Table Table Size 1400 mm × 600 mm Total Height 1960 mm Max Travel Front-Back 150 mm Max Travel Left-Right 220 mm Flat Panel Detector Sensor / Scintillator Amorphous Silicon / Cesium Iodide Imaging Area 430 × 430 mm² Pixel Array 3072 × 3072 Pixel Size 140 μm A/D Conversion 16-bit Limiting Resolution 3.57 Ip/mm Maximum Linear Dose 70 μGy Dynamic Range >80 dB Image Readout Time 2–4 s Veterinary Software Interface 16 languages, worklist supported Data Acquisition DICOM Worklist, BDT/CDT, HL7 or manual acquisition Image Tools Unlimited zoom, rotation, mirroring, measurement tools Emergency Registration Quick and secure patient registration Image Processing Window/Level, gamma, filters, noise reduction Measurement Functions TPLO, TTA, HD, etc. Export Formats PNG, TIFF, BMP, DICOM Presets Over 400 programs, freely customizable PACS Integration Yes



